EMMERICH UPS Galaxy Net 15 GNT15

https://www.bhinneka.com/web/image/product.product/9864/image_1920?unique=5725bd3
3319128929
|
Harga
-

159920500.0 IDR Rp 159.920.500 0% Rp 159.920.500
Harga sudah termasuk PPN

Rp 144.072.523 Termasuk PPN

Not Available For Sale

Cicilan
-
Mulai dari Rp 13.738.875/bulan. Lihat cicilan lainnya
Estimasi
Siap dikirim 2-5 hari
  • Merek
  • Lokasi

Variant ini tidak tersedia.

Total Rp 159.920.500
Anda sudah mencapai maksimal pembelian
Informasi Toko
Dijual dan dikirim oleh Bhinneka, DKI Jakarta
Garansi
5 Years Local Official Distributor Warranty

Syarat dan Ketentuan
Jaminan 30-hari uang-kembali
Pengiriman: 2-3 Hari Kerja

  • Three Phase UPS, Capacity 15000VA/12000W, PF 0.8, Voltage 285-485VAC, Backup 10 Minutes
  • Unit Utama
  • Spesifikasi
    Daya Keluar15000VA / 12000W
    Form FactorTower
    Baterai
    • Battery Type and Numbers : 12VDC x 32 Pcs (29-32 pcs adjustable)
    • Nominal Battery Voltage : 384 VDC (Based on 32pcs Batteries)
    • Charging current (max) : Default 10A; Max : 40A, 5A full load
    • Charging Voltage : 432 VDC ( Based on 32 pcs Batteries)
    Voltase Masuk
    • Nominal Voltage : 3 x 380 VAC/400VAC
    • Acceptable Voltage Range : 285-485VAC
    • Frequency Range : 50/60 Hz +- 10%
    • Power Factor : 0.8
    Antarmuka / Interface
    • Modbus RS-232/RS485
    • Dry Contact
    • Optional SNMP
    Back-Up Time Full Load10 minutes
    Dimensi Produk656 x 405 x 817mm(DxWxH)
    Voltase Keluar
    • Output Voltage : 3 x 380VAC/400VAC (3Ph + N)
    • Precision : Stationary : 1%; Transitory : +- 5% (load Variations 100-0-100%)
    • Frequency Range : 50/60 Hz Synchronized +- 1%; with main absent +- 0.1 Hz
    • Max Synchronized Speed : +- 1Hz/s
    • Current Crest Ratio : 3:1
    • Harmonic Distortion : <= 3% Thd (Linear Load); <= 5% Thd (Non-Linear Load)
    • Waveform (Battery Mode) : Pure Sinewave
    • Total Harmonic disortion (THDv) : <2% (Linear Load); <5% (non linear load)
    • Dynamic recovery time : 3 cycles at 90% of the static value
    • Admissible Overload : 110% for 10 min; 150% for 60 sec; > 160% for 200ms
    • Admissible Crest Factor : 3:1
    • Admissible Power Factor : 0.6-1 (inductive capacitive)
    • Imbalance Output voltage @ 100% unbalanced load : <1%
    • Total Harmonic disortion (THDv) : High Overload, short circuit : RMS voltage limit; High crest factor curent; Peak voltage limit
    Lain-lain
    • Static bypass : Type : Solid state; Voltage : 380 VAC/400VAC (3Ph+N); Frequency : 50/60Hz; Activation Criterion : microprocessor control; Transfer Time : zero; Admissible overload : 150% for 1 Hour; 180% for 30 sec; > 200% for 200ms; Transfer to Bypass : Immediate for overloads above 160%; Retransfer : Automatic after alarm clear
    • Maintenance Bypass : Type : without interruption; Voltage : 380VAC/400VAC (3Ph+N); Freuency : 50/60 Hz
    • Overall Efficiency : Line Mode : 93%; Battery Mode : 93%
    • ECO Mode (Non-Parallel Models)
    • EPO Function
    • Standard : IEC 61000-4-5 Protein surge
    • Operating Temperature : 0-35 C continuous running, 40 C 8-hour running at nomial input voltage, recharging batteries and no overload, 45 C derating to 85% with linear load
    • Humidity : 0-90% (non-condensing)
    • Noise Level : Less Than 70dBA 1 Meter
    Review